The Effect of Simulated Dose Reduction on the Performance of Artificial Intelligence in Chest Radiography

  • Rijksuniversiteit Groningen, Universitair Medisch Centrum Groningen, Afdeling Radiotherapie
  • Johan Bernoulli Institute for Mathematics and Computer Science, University of Groningen
  • University of Groningen, University Medical Center Groningen, Data Science Center in Health

Onderzoeksoutput: Article › Academic › peer review

Samenvatting

Chest imaging plays a pivotal role in screening and monitoring patients, and various predictive artificial intelligence (AI) models have been developed in support of this. However, little is known about the effect of decreasing the radiation dose and, thus, image quality on AI performance. This study aims to design a low-dose simulation and evaluate the effect of this simulation on the performance of CNNs in plain chest radiography. Seven pathology labels and corresponding images from Medical Information Mart for Intensive Care datasets were used to train AI models at two spatial resolutions. These 14 models were tested using the original images, 50% and 75% low-dose simulations. We compared the area under the receiver operator characteristic (AUROC) of the original images and both simulations using DeLong testing. The average absolute change in AUROC related to simulated dose reduction for both resolutions was <0.005, and none exceeded a change of 0.014. Of the 28 test sets, 6 were significantly different. An assessment of predictions, performed through the splitting of the data by gender and patient positioning, showed a similar trend. The effect of simulated dose reductions on CNN performance, although significant in 6 of 28 cases, has minimal clinical impact. The effect of patient positioning exceeds that of dose reduction.
Originele taal-2English
TijdschriftJournal of Imaging
Volume11
Nummer van het tijdschrift3
StatusPublished - 19 mrt. 2025

Duurzame ontwikkelingsdoelstellingen van de VN

Deze output draagt bij aan de volgende duurzame ontwikkelingsdoelstelling(en)

  1. SDG 03 – Goede gezondheid en welzijn
    SDG 03 – Goede gezondheid en welzijn
  2. SDG 17 - Partnerschap om de doelen te bereiken
    SDG 17 Partnerschap om de doelen te bereiken

Keywords

  • kunstmatige intelligentie
  • dosisverlaging
  • geluid
  • beeldkwaliteit
  • thoraxradiografie

Research Focus Areas Hanze University of Applied Sciences

  • Healthy Ageing

Research Focus Areas Research Centre or Centre of Expertise

  • Kwetsbaarheid en passende zorg

Publinova thema's

  • Overig
  • Gezondheid

Vingerafdruk

Duik in de onderzoeksthema's van 'The Effect of Simulated Dose Reduction on the Performance of Artificial Intelligence in Chest Radiography'. Samen vormen ze een unieke vingerafdruk.

Citeer dit