Doorgaan naar hoofdnavigatie Doorgaan naar zoeken Ga verder naar hoofdinhoud

Reliability and validity of the steep ramp test to assess cardiorespiratory fitness in apparently healthy adults

  • Rijksuniversiteit Groningen, Universitair Medisch Centrum Groningen, Afdeling Bewegingswetenschappen
  • Martini Hospital, Burn Centre, Alliance of Dutch Burn Care (ADBC)
  • Maastricht University, Faculty of Health, Medicine and Life Sciences, Institute of Nutrition and Translational Research in Metabolism (NUTRIM), Department of Nutrition and Movement Sciences
  • Maastricht University, School of Nutrition and Translational Research in Metabolism (NUTRIM), Department of Surgery
  • Zuyd
  • University Medical Center Utrecht, Wilhelmina Children’s Hospital, Child Development and Exercise Center

Onderzoeksoutput: Article › Academic › peer review

Samenvatting

Purpose
To investigate the test-retest reliability and validity of the steep ramp test (SRT), a short and practical maximal exercise test on a cycle ergometer, for assessing CRF in apparently healthy adults aged 25–85 years.

Methods
To determine test-retest reliability, the reliability group performed the SRT twice within 2–14 days. The intraclass correlation coefficient (ICC) for the attained work rate at peak exercise (WRpeak) at the SRT was calculated and agreement was evaluated using Bland-Altman plots. The smallest detectable change (SDC) was calculated. To determine criterion and construct validity of the SRT, the validity group performed both the SRT and cardiopulmonary exercise testing (CPET) on a single day. Correlation analyses were used to assess the relationship between SRT WRpeak and oxygen uptake (V̇O2) at peak exercise (V̇O2peak), V̇O2 at the first ventilatory threshold (V̇O2VT1), and the oxygen uptake efficiency slope (OUES) achieved during CPET.

Results
In the reliability group (n = 66, 35 males), the ICC for SRT WRpeak was 0.992. Limits of agreement ranged from − 18.6 W (-5.4%) to 24.1 W (6.5%). The SDC was 15 W, 0.2 W/kg, or 4.2%. In the validity group (n = 61, 33 males), CPET V̇O2peak, V̇O2VT1, and OUES showed Pearson’s correlation coefficients with SRT WRpeak of 0.936, 0.806, and 0.891, respectively. The following equation predicts V̇O2peak (mL/min) from SRT performance: -280.784 + (8.680 × SRT WRpeak (in W)) (adjusted R2 = 0.874, SEE = 318.476).

Conclusion
This study demonstrated excellent test-retest reliability, very high criterion validity, and high construct validity of the SRT for assessing CRF in apparently healthy adults.
Originele taal-2English
Pagina's (van-tot)3115-3127
Aantal pagina's13
TijdschriftEuropean Journal of Applied Physiology
Volume126
Nummer van het tijdschrift6
DOI's
StatusE-pub ahead of print - 19 jan. 2026

Duurzame ontwikkelingsdoelstellingen van de VN

Deze output draagt bij aan de volgende duurzame ontwikkelingsdoelstelling(en)

  1. SDG 03 – Goede gezondheid en welzijn
    SDG 03 – Goede gezondheid en welzijn
  2. SDG 17 - Partnerschap om de doelen te bereiken
    SDG 17 Partnerschap om de doelen te bereiken

Keywords

  • fysieke fitheid
  • gezonde populatie
  • inspanningstest
  • klinimetrische eigenschappen
  • publieke gezondheid

Research Focus Areas Hanze University of Applied Sciences

  • Healthy Ageing

Research Focus Areas Research Centre or Centre of Expertise

  • Kwetsbaarheid en passende zorg

Publinova thema's

  • Overig

Vingerafdruk

Duik in de onderzoeksthema's van 'Reliability and validity of the steep ramp test to assess cardiorespiratory fitness in apparently healthy adults'. Samen vormen ze een unieke vingerafdruk.

Citeer dit