Reconstruction of high resolution MLC leaf positions using a low resolution detector for accurate 3D dose reconstruction in IMRT

  • R. Visser
  • , J. Godart
  • , D.J.L. Wauben
  • , J.A. Langendijk
  • , A.A. van 't Veld
  • , E.W. Korevaar
  • University of Groningen, University Medical Center Groningen, Department of Radiation Oncology

Onderzoeksoutput: Article › Academic › peer review

Samenvatting

In pre-treatment dose verification, low resolution detector systems are unable to identify shifts of individual leafs of high resolution multi leaf collimator (MLC) systems from detected changes in the dose deposition. The goal of this study was to introduce an alternative approach (the shutter technique) combined with a previous described iterative reconstruction method to accurately reconstruct high resolution MLC leaf positions based on low resolution measurements. For the shutter technique, two additional radiotherapy treatment plans (RT-plans) were generated in addition to the original RT-plan; one with even MLC leafs closed for reconstructing uneven leaf positions and one with uneven MLC leafs closed for reconstructing even leaf positions. Reconstructed leaf positions were then implemented in the original RT-plan for 3D dose reconstruction. The shutter technique was evaluated for a 6 MV Elekta SLi linac with 5 mm MLC leafs (Agility(™)) in combination with the MatriXX Evolution detector with detector spacing of 7.62 mm. Dose reconstruction was performed with the COMPASS system (v2.0). The measurement setup allowed one row of ionization chambers to be affected by two adjacent leaf pairs. Measurements were obtained for various field sizes with MLC leaf position errors ranging from 1.0 mm to 10.0 mm. Furthermore, one clinical head and neck IMRT treatment beam with MLC introduced leaf position errors of 5.0 mm was evaluated to illustrate the impact of the shutter technique on 3D dose reconstruction. Without the shutter technique, MLC leaf position reconstruction showed reconstruction errors up to 6.0 mm. Introduction of the shutter technique allowed MLC leaf position reconstruction for the majority of leafs with sub-millimeter accuracy resulting in a reduction of dose reconstruction errors. The shutter technique in combination with the iterative reconstruction method allows high resolution MLC leaf position reconstruction using low resolution measurements with sub-millimeter accuracy.

Originele taal-2English
Pagina's (van-tot)642-649
TijdschriftPhysics in Medicine & Biology
Volume61
Nummer van het tijdschrift23
DOI's
StatusPublished - 7 nov. 2016

Duurzame ontwikkelingsdoelstellingen van de VN

Deze output draagt bij aan de volgende duurzame ontwikkelingsdoelstelling(en)

  1. SDG 03 – Goede gezondheid en welzijn
    SDG 03 – Goede gezondheid en welzijn
  2. SDG 17 - Partnerschap om de doelen te bereiken
    SDG 17 Partnerschap om de doelen te bereiken

Keywords

  • radiotherapie

Research Focus Areas Hanze University of Applied Sciences

  • Healthy Ageing

Research Focus Areas Research Centre or Centre of Expertise

  • Kwetsbaarheid en passende zorg

Publinova thema's

  • Overig

Vingerafdruk

Duik in de onderzoeksthema's van 'Reconstruction of high resolution MLC leaf positions using a low resolution detector for accurate 3D dose reconstruction in IMRT'. Samen vormen ze een unieke vingerafdruk.

Citeer dit