Multicriteria optimization enables less experienced planners to efficiently produce high quality treatment plans in head and neck cancer radiotherapy

Roel G J Kierkels, Ruurd Visser, Hendrik P Bijl, Johannes A Langendijk, Aart A van 't Veld, Roel J H M Steenbakkers, Erik W Korevaar

Onderzoeksoutput: ArticleAcademicpeer review

Samenvatting

OBJECTIVES: To demonstrate that novice dosimetry planners efficiently create clinically acceptable IMRT plans for head and neck cancer (HNC) patients using a commercially available multicriteria optimization (MCO) system.

METHODS: Twenty HNC patients were enrolled in this in-silico comparative planning study. Per patient, novice planners with less experience in dosimetry planning created an IMRT plan using an MCO system (RayStation). Furthermore, a conventionally planned clinical IMRT plan was available (Pinnacle(3)). All conventional IMRT and MCO-plans were blind-rated by two expert radiation-oncologists in HNC, using a 5-point scale (1-5 with 5 the highest score) assessment form comprising 10 questions. Additionally, plan quality was reported in terms of planning time, dosimetric and normal tissue complication probability (NTCP) comparisons. Inter-rater reliability was derived using the intra-class correlation coefficient (ICC).

RESULTS: In total, the radiation-oncologists rated 800 items on plan quality. The overall plan score indicated no differences between both planning techniques (conventional IMRT: 3.8 ± 1.2 vs. MCO: 3.6 ± 1.1, p = 0.29). The inter-rater reliability of all ratings was 0.65 (95% CI: 0.57-0.71), indicating substantial agreement between the radiation-oncologists. In 93% of cases, the scoring difference of the conventional IMRT and MCO-plans was one point or less. Furthermore, MCO-plans led to slightly higher dose uniformity in the therapeutic planning target volume, to a lower integral body dose (13.9 ± 4.5 Gy vs. 12.9 ± 4.0 Gy, p < 0.001), and to reduced dose to the contra-lateral parotid gland (28.1 ± 11.8 Gy vs. 23.0 ± 11.2 Gy, p < 0.002). Consequently, NTCP estimates for xerostomia reduced by 8.4 ± 7.4% (p < 0.003). The hands-on time of the conventional IMRT planning was approximately 205 min. The time to create an MCO-plan was on average 43 ± 12 min.

CONCLUSIONS: MCO planning enables novice treatment planners to create high quality IMRT plans for HNC patients. Plans were created with vastly reduced planning times, requiring less resources and a short learning curve.

Originele taal-2English
TijdschriftRadiation oncology
Volume10
Nummer van het tijdschrift87
DOI's
StatusPublished - 12 apr. 2015

Keywords

  • algoritmen
  • carcinoma, squamous cel
  • computersimulatie
  • vrouwelijk
  • hoofd en nek neoplasma's
  • mensen
  • mannelijk
  • prospectieve studies
  • kwaliteitsborg, gezondheid
  • radiometrie
  • radiotherapie dosering
  • radiotherapie, planning, computergesteund
  • radiotherapie, intensiteit gemoduleerd

Vingerafdruk

Duik in de onderzoeksthema's van 'Multicriteria optimization enables less experienced planners to efficiently produce high quality treatment plans in head and neck cancer radiotherapy'. Samen vormen ze een unieke vingerafdruk.

Citeer dit