Agreement of measurement of body composition with seven alternative electrode positions on the hand compared to the standard protocol with single-frequency 50 kHz bioelectrical impedance in healthy young adults

Vertaalde titel van de bijdrage: De overeenstemming van de meting van lichaamssamenstelling met zeven alternatieve elektrodeposities op de hand vergeleken met het standaardprotocol met enkelvoudige frequentie van 50 kHz bio-elektrische impedantie bij gezonde jongvolwassenen

Geranda Slager (First author), Thirza Borkhuis, Susan Hoeksema, Martine Sealy

Onderzoeksoutput: AbstractAcademic

Samenvatting

Rationale
In bioelectrical impedance analysis (BIA) measurements, one pair of electrodes is typically placed dorsal on the right hand (position A) and one pair on the foot. In patients with fragile skin, scars or wounds, this dorsal hand placement is not always possible. This study compares agreement of BIA measurements at seven alternative placements with position A.
Methods
BIA measurements were performed with the Bodystat-500 using eight combinations of hand electrodes: at the dorsal side of the hand (position A) or dorsal side hand-forearm (position B and C); at the palmar side of the hand (position D) or palmar side hand-forearm (position E and F) or mixed palmar-dorsal side of the hand (position G and H). ICCs were used to compare alle outcomes to position A. Changes in fat mass ∆FM, fat-free mass ∆FFM and appendicular skeletal muscle mass ∆ASMM were calculated using Kyle’s formula.
Results
Seventy healthy Caucasian participants were measured: median age 22 years, IQR 21-23; mean BMI 22.8 ± 2.5 kg/m². Electrode positions D,G and H showed an ICC 0.99-1.00 for ∆FM, ∆FFM and ∆ASMM with minimal changes in ∆FFM and ∆FM: 0.1–0.4 kg ± 0.3 kg and ∆ASMM: 0.0–0.2 kg ± 0.2 kg. Measurements at position B, C, E, and F showed significant and clinically relevant differences with ∆FM and ∆FFM: 3.8–4.0 kg ± 1.1 kg and ∆ASMM: 2.0–2.1 kg ± 0.6 kg, with ICCs 0.96-0.97.
Conclusion
Alternatively to the typical electrode placement on the dorsal side of the hand, this study demonstrates that three alternative placements results in an excellent agreement with only minimal changes in FFM, FM and ASMM. In practice, placing electrodes at more proximal positions on the forearm should be avoided. Alternatively, we recommend a mixed or palmar electrode placement on the hand.
Vertaalde titel van de bijdrage De overeenstemming van de meting van lichaamssamenstelling met zeven alternatieve elektrodeposities op de hand vergeleken met het standaardprotocol met enkelvoudige frequentie van 50 kHz bio-elektrische impedantie bij gezonde jongvolwassenen
Originele taal-2English
DOI's
StatusPublished - 18 sep. 2024
EvenementESPEN conference 2024 - Milan, Milaan, Italy
Duur: 7 sep. 202410 sep. 2024
https://espencongress.com/

Conference

ConferenceESPEN conference 2024
Land/RegioItaly
StadMilaan
Periode7/09/2410/09/24
Internet adres

Keywords

  • bio-impedantie
  • lichaamssamenstelling
  • spiermassa
  • clinimetry

Vingerafdruk

Duik in de onderzoeksthema's van 'De overeenstemming van de meting van lichaamssamenstelling met zeven alternatieve elektrodeposities op de hand vergeleken met het standaardprotocol met enkelvoudige frequentie van 50 kHz bio-elektrische impedantie bij gezonde jongvolwassenen'. Samen vormen ze een unieke vingerafdruk.

Citeer dit