TY - JOUR
T1 - Test-retest reliability and concurrent validity of the Adapted Short QUestionnaire to ASsess Health-enhancing physical activity (Adapted-SQUASH) in adults with disabilities
AU - Seves, Bregje L
AU - Hoekstra, Femke
AU - Schoenmakers, Jorrit W A
AU - Brandenbarg, Pim
AU - Hoekstra, Trynke
AU - Hettinga, Florentina J
AU - Dekker, Rienk
AU - van der Woude, Lucas H.V.
AU - van der Schans, Cees P.
PY - 2021
Y1 - 2021
N2 - The current study determined the test-retest reliability and concurrent validity of the Adapted Short QUestionnaire to ASsess Health-enhancing physical activity (Adapted-SQUASH) in adults with disabilities. Before filling in the Adapted-SQUASH twice with a recall period of 2 weeks, participants wore the Actiheart activity monitor up to 1 week. For the test-retest reliability (N = 68), Intraclass correlation coefficients (ICCs) were 0.67 (p < 0.001) for the total activity score (min x intensity/week) and 0.76 (p < 0.001) for the total minutes of activity (min/week). For the concurrent validity (N = 58), the Spearman correlation coefficient was 0.40 (p = 0.002) between the total activity score of the first administration of the Adapted-SQUASH and activity energy expenditure from the Actiheart (kcals kg-1 min-1). The ICC was 0.22 (p = 0.027) between the total minutes of activity assessed with the first administration of the Adapted-SQUASH and Actiheart. The Adapted-SQUASH is an acceptable measure to assess self-reported physical activity in large populations of adults with disabilities but is not applicable at the individual level due to wide limits of agreement. Self-reported physical activity assessed with the Adapted-SQUASH does not accurately represent physical activity assessed with the Actiheart in adults with disabilities, as indicated with a systematic bias between both instruments in the Bland-Altman analysis.
AB - The current study determined the test-retest reliability and concurrent validity of the Adapted Short QUestionnaire to ASsess Health-enhancing physical activity (Adapted-SQUASH) in adults with disabilities. Before filling in the Adapted-SQUASH twice with a recall period of 2 weeks, participants wore the Actiheart activity monitor up to 1 week. For the test-retest reliability (N = 68), Intraclass correlation coefficients (ICCs) were 0.67 (p < 0.001) for the total activity score (min x intensity/week) and 0.76 (p < 0.001) for the total minutes of activity (min/week). For the concurrent validity (N = 58), the Spearman correlation coefficient was 0.40 (p = 0.002) between the total activity score of the first administration of the Adapted-SQUASH and activity energy expenditure from the Actiheart (kcals kg-1 min-1). The ICC was 0.22 (p = 0.027) between the total minutes of activity assessed with the first administration of the Adapted-SQUASH and Actiheart. The Adapted-SQUASH is an acceptable measure to assess self-reported physical activity in large populations of adults with disabilities but is not applicable at the individual level due to wide limits of agreement. Self-reported physical activity assessed with the Adapted-SQUASH does not accurately represent physical activity assessed with the Actiheart in adults with disabilities, as indicated with a systematic bias between both instruments in the Bland-Altman analysis.
KW - bewegen (activiteit)
KW - volwassenen
KW - gehandicapten
KW - physical activities
KW - adults
KW - disabilities
U2 - 10.1080/02640414.2020.1850983
DO - 10.1080/02640414.2020.1850983
M3 - Article
C2 - 33295236
SN - 1466-447X
VL - 39
SP - 875
EP - 886
JO - Journal of Sports Sciences
JF - Journal of Sports Sciences
IS - 8
ER -