Intra- and inter-rater reliability of biceps thickness assessment by ultrasound in elderly

João Pedro Pinho, Rita Azevedo, Paula Rocha, Joana Silveira, Willemke Nijholt, Harriët Jager-Wittenaar

Research output: Contribution to conferencePosterOther research output

34 Downloads (Pure)

Abstract

Rationale: Although ultrasound has been reported as valid and reliable tool to assess muscle size in older adults1, little is known about intra-rater reliability (intra-RR) and inter-rater reliability (inter-RR) of BodyMetrix in specific to assess small muscles. Therefore, in this study we aimed to assess intra-RR and inter-RR of biceps muscle size (thickness) in elderly.Methods: Thirty elderly (81.9±6.3 years; 80% women; BMI 26.7±5.3 kg/m2) living in a Portuguese nursing home/residence were included. To assess procedural intra-RR and inter-RR, ultrasound measurements were performed by two raters (R1, R2, beginners level) by BodyMetrixTM BX2000, on the biceps of the right arm. R1 repeated the ultrasound measurement once. To assess measurement intra-RR and inter-RR, images were analyzed by three raters (R1, R2, and R3 [experienced level]). Agreement was analyzed by intraclass correlation coefficient. ICC values of 0.50 to 0.75 were considered moderate to good, and >0.75 as good to excellent. Statistical significance was set at p<0.05.Results: Mean muscle thickness at 1st and 2nd measurement (R1) was 23.4±4.5 and 23.7±3.8 mm, respectively. For procedural intra-RR, ICC was 0.630. For inter-RR of image 1 (R1) vs. image 2 (R2), ICC was 0.622. For inter-RR of image 2 (R2) vs. image 3 (R1) ICC was 0.534. For measurement reliability, ICCs for intra-RR of R1 and R2 were 0.865 and 0.766, respectively. ICCs for inter-RR of R1 vs. R2, R2 vs. R3, and R1 vs. R3 were 0.865, 0.800, and 0.815, respectively. All ICCs were statistically significant (p≤0.001).Conclusion: The results of our study indicate that procedural reliability of biceps muscle size as assessed by BodyMetrix in elderly is moderate to good, and measurement reliability is good to excellent. Increasing the level of experience may further improve procedural reliability.
Original languageEnglish
Publication statusPublished - Aug 2017
EventESPEN - The Hague, Netherlands
Duration: 9 Sep 201712 Sep 2017

Conference

ConferenceESPEN
CountryNetherlands
CityThe Hague
Period9/09/1712/09/17

Keywords

  • reliability
  • ultrasound
  • muscles

Fingerprint Dive into the research topics of 'Intra- and inter-rater reliability of biceps thickness assessment by ultrasound in elderly'. Together they form a unique fingerprint.

  • Cite this

    Pinho, J. P., Azevedo, R., Rocha, P., Silveira, J., Nijholt, W., & Jager-Wittenaar, H. (2017). Intra- and inter-rater reliability of biceps thickness assessment by ultrasound in elderly. Poster session presented at ESPEN, The Hague, Netherlands.