Abstract
Within the Flexnode Plus project the long-term degradation characteristics of a proton exchange membrane (PEM) electrolyzer (5.5 kW, AC, 1 Nm3/h H2) and fuel cell (1.0 kW, DC, 0.9 Nm3/h) was experimentally tested. The electrolyzer unit was operated at various loads and pressures for approximately 750 hours in total, while the fuel cell was operated at a constant load of 1 Ω resistance for approximately 1120 hours in total. The efficiency of the hydrogen production in the electrolyzer and the electricity production in the fuel cell was expressed using the hourly average system efficiency and average cell efficiency. In
order to predict the state of health and remaining lifetime of the electrolyzer cell and fuel cell, the decay of the cell voltage over time was monitored and the direct mapping from aging data method was used.
The electrolyzer cell showed a stable cell voltage and cell efficiency in the studied time period, with an average cell voltage decay rate of 0.5 μV/h. The average cell voltage of the fuel cell dropped with a rate of 2 μV/h during the studied time period.
order to predict the state of health and remaining lifetime of the electrolyzer cell and fuel cell, the decay of the cell voltage over time was monitored and the direct mapping from aging data method was used.
The electrolyzer cell showed a stable cell voltage and cell efficiency in the studied time period, with an average cell voltage decay rate of 0.5 μV/h. The average cell voltage of the fuel cell dropped with a rate of 2 μV/h during the studied time period.
Original language | English |
---|---|
Number of pages | 12 |
Publication status | Published - 10 Dec 2019 |
Keywords
- electrolyzer
- fuel cells
- efficiency
- proton exchange membrane